The Irregular Response of Flat Plate Structures to Horizontal Deformation for Engineering Decisions
Downloads
This study examines the structural response of a seven-story reinforced concrete building with a dual system, focusing on shear forces, stiffness, and inter-story variations. Designed in accordance with SNI 1726-2019 for Jakarta, the study considers dead loads, live loads, wind loads, rain loads, and earthquake loads. Analysis on the second floor (6.2 m above the foundation) indicates that the inter-story deflections meet the permissible limits, with a maximum deviation of 64.615 kN at the roof and 49.23 kN from floors 2 to 6. Static shear forces reached 41,826.62 kN (X) and 4,182.62 kN (Y), while dynamic shear forces reached 4,697.28 kN (X) and 5,057.97 kN (Y), meeting the static force requirement of 100%. Overall, the shear forces, stiffness, and inter-story deviations of Building B demonstrate an effective structural response to earthquake activity. Engineers are expected to master the behavior of irregularities in structural elements due to earthquake loads so that they can make informed decisions in construction planning and its implementation in the field.
(BSN), B. S. N. (2019). Structural Concrete Requirements for Buildings and Explanation (SNI 2847:2019). In Indonesian National Standard (SNI) (Issue 8).
Indonesian National Standards Agency. (2019). Indonesian National Standard SNI 1726:2019. Earthquake Resilience Planning Procedures for Building and Non-Building Structures, 1–248.
National Standards Agency. (2020). Minimum design load and Related criteria for buildings and other structures. National Standards Agency 1727:2020, 8, 1–336.
Cahyana, D. N. M. D., Sinarta, I. N., & Sarassantika, I. P. E. (2022). The Design of The Flat Slab System With Drop Panel in The Sukawati Market Building. Journal of Infrastrcuture Planning and Engfineering, 1(2), 75–80.
https://doi.org/https://doi.org/10.22225/jipe.1.2.2022.75-80
Hs, E. S. E. S. (2002). Design and Detailing. February.
I Gusti Ngurah Agung Eka Arya, T., Nyoman Parthin Indra, M., I Nengah, S., I Wayan Gde Erick, T., & Putu Ellsa, S. (2023). Analysis of Penel Drop-Off on Shear Slip At Flat Slab in the Animal Hospital Education Building of the Faculty of Veterinary Medicine (Rshpfkh), Udayana University. Journal of Infrastructure Planning and Engineering (JIPE), 2(2), 23–26. https://doi.org/10.22225/jipe.2.2.2023.23-26
I Wayan Maesa Andreasnata, I Nengah Sinarta, Ni Komang Armaeni, I. P. Ellsa Sarassantika, Dang Thanh Trung, Cintantya Budi Casita, Roro Sulaksitaningrum, & Sudarno P. Tampubolon. (2022). Column structure strengthening with FRP (Fiber Reinforced Polymer) due to story addition. Journal of Infrastructure Planning and Engineering (JIPE), 1(1), 38–45. https://doi.org/10.22225/jipe.1.1.2022.38-45
Primakov, A., & Leo, E. (2019). Efficiency study of flat slab system using post-tension and conventional methods. JMTS: Journal of Civil Engineering Partners, 2(1), 133. https://doi.org/10.24912/jmts.v2i1.3418
Pungus, M. A. R. (2020). A Comprehensive Study of Flat Slab System with Drop Panel and Conventional Slab System in a 10-Storey Reinforced Concrete Building. 1–23.
Putra, I. N. R. D., Sinarta, I. N., & Bagiarta, I. Y. K. (2020). Analysis of the Strength of Bamboo Structure in the Construction of the Entry Building Green School Ubud. Ukarst, 4(1), 1–15.
Setiawan, A. (2016). The design of reinforced concrete structures is based on SNI 2847:2013. Erlangga.
Teruna, D. R., & Prawira, S. (2016). Comparative Study of the Use of Flat Plate and Flat Slab with Drop Panel on Building Structures is reviewed in terms of Volume. USU Journal of Civil Engineering, 1(1), 1–8.
Varghese, V. (2020). A Project Report On Analysis And Design Of Multistorey Residential Building Using Etabs Department of Civil Engineering.
Wiranata, I. M. K., & Sinarta, I. N. (2023). Analysis Of Consolidation And Safe Numerical Value In Soft Clay Soil Stabilization Efforts With Prefabricated Vertical Drain (PVD). November, 16–17.